DEVELOPMENT OF A PROCESS FOR THE COMPETITIVE LATERAL FLOW IMMUNOCHROMATOGRAPHY ASSAY (LFIA) STRIP FOR RAPID DETECTION OF OCHRATOXIN A (OTA) IN COFFEE

Đức Minh Tống1, , Nguyễn Văn Chuyên1, Bùi Khánh Toàn2, Nguyễn Văn Ba3, Nguyễn Thị Thu Trang1, Lê Tuấn Anh1, Hoàng Thị Trường1, Đoàn Bảo Hà1, Nguyễn Mạnh Tuấn4, Tạ Quang Thành5, Vũ Hoàng Anh6
1 Khoa Vệ sinh Quân đội, Học viện Quân y
2 Viện Vệ sinh Dịch tễ Tây Nguyên
3 Bệnh viện Quân y 175
4 Viện Sốt rét, Ký sinh trùng, Côn trùng Trung ương
5 Bệnh viện Bắc Thăng Long
6 Trung tâm Kiểm soát bệnh tật Thành phố Hà Nội

Main Article Content

Abstract

Objective: To develop a process for the competitive lateral flow immunochromatography assay (LFIA) strip for rapid detection of Ochratoxin A (OTA) in coffee. Methods: The study was conducted through laboratory experiments following an 8-step process, with each step involving the optimization of various parameters to enhance the sensitivity of the test strip. The product test strips are evaluated for the limit of detection, the stability, the specificity, cross-reactivity and from there, a test strip manufacturing process is developed. Results: The optimal size of the gold nanoparticles was determined to be 30 nm, which enhanced the sensitivity and generated clear color signals on the test strip. The optimal concentration of antibodies coated on the gold nanoparticles was 10 µg/ml. The optimal concentration of OTA-BSA applied on the test line was 1 mg/ml, which produced a strong and stable color signal, allowing clear distinction between positive and negative samples. The limit of detection (LOD) was 6 µg/L. The stability of the test strip was maintained for 6 months when stored at 4°C and 25°C. Conclusion: We have successfully developed a competitive lateral flow immunoassay strip for the detection of Ochratoxin A in coffee with the limit of detection (LOD): 6 µg/L, the specificity: 90%, and the stability for 6 months when stored at 4°C and 25°C.

Article Details

References

. YN Gao, CQ Wu, JQ Wang, et al. N. Metabolomic Analysis Reveals the Mechanisms of Hepatotoxicity Induced by Aflatoxin M1 and Ochratoxin A. Toxins (Basel). 2022 Feb 15; 14(2):141. DOI: 10.3390/toxins14020141.
2. IARC Working Group on the Evaluation of Carcinogenic Risks to Humans. Some traditional herbal medicines, some mycotoxins naphthalene and styrene. IARC Monogr Eval Carcinog Risks Hum. 2002; 82:1-556. PMCID: PMC4781602.
3. Stoev SD. Long term preliminary studies on toxic and carcinogenic effect of individual or simultaneous exposure to ochratoxin A and penicillic acid in mice. Toxicon. 2020 Sep; 184:192-201. DOI: 10.1016/j.toxicon.2020.06.013.
4. Wong RC, Harley YT. Lateral Flow Immunoassay. Humana Press. Springer Science & Business Media. 2009. DOI 10.1007/978-1-59745-240-3.
5. Claudio Parolo, Amadeo Sena-Torralba, José Francisco Bergua, et al. Tutorial: Design and fabrication of nanoparticlebased lateral-flow immunoassays. Nature Protocols. 2020 Dec; 15(12): 3788-3816. DOI: 10.1038/s41596-020-0357-x.
6. Yiqiang Chen, Qian Chen, Miaomiao Han, et al. Development and optimization of a multiplex lateral flow immunoassay for the simultaneous determination of three mycotoxins in corn, rice and peanut. Food Chemistry. 2016 Dec 15; 213:478-484. DOI: 10.1016/j.foodchem. 2016.06.116.
7. Xin Li, Peiwu Li, Qi Zhang, et al. Multi-component immunochromatographic assay for simultaneous detection of aflatoxin B1, ochratoxin A and zearalenone in agro-food. Biosensors and Bioelectronics. 2013 Nov 15; 49:426-32. DOI: 10.1016/j.bios.2013.05.039.
8. Jihea Moon, Giyoung Kim, Sangdae Lee. Development of nanogold-based lateral flow immunoassay for the detection of Ochratoxin A in buffer systems. Journal of Nanoscience and Nanotechnology. 2013 Nov; 13(11):7245-9. DOI: 10.1166/jnn.2013.8099.